Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Actas Dermosifiliogr ; 113(2): 134-140, 2022 Feb.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-35244560

RESUMO

BACKGROUND AND OBJECTIVE: Acral lentiginous melanoma (ALM) arises in areas that are not generally exposed to UV radiation. Chronic trauma has been hypothesized to play a role in the development of this tumor. The aim of this study was to analyze the association between the presence and characteristics of ALM and location in stress- and non-stress-bearing areas. MATERIAL AND METHODS: Observational, descriptive analysis. For 95 patients with ALM evaluated at Fundación Clínica Vida in Medellin, Colombia between January 2016 and August 2020 we collected demographic, histologic and clinical variables and assigned the patients to 2 groups depending on whether their tumor was located in a stress-bearing area or not. RESULTS: Ninety-five patients (36 men and 59 women) with a median age of 59 years were studied. ALMs were more common in stress-bearing areas than in non-stress-bearing areas (58 [61%] vs. 17 [17.8%]). A history of direct trauma at the site of the tumor was reported in 18.9% of the cases (p = .025) and was most common in patients with nail lesions. Invasive ALMs in stress-bearing areas had a greater Breslow thickness (p = .006) and higher ulceration rates than those in non-stress-bearing areas (p = .018). CONCLUSIONS: ALM on both the feet and hands is more common in stress-bearing areas. Our findings support the hypothesis that mechanical stress may have a pathogenic role in ALM.

2.
Actas dermo-sifiliogr. (Ed. impr.) ; 113(2): 134-140, Feb. 2022. ilus, tab
Artigo em Espanhol | IBECS | ID: ibc-205921

RESUMO

Antecedentes y objetivo: El melanoma lentiginoso acral (MLA) se presenta en zonas con poca exposición a la radiación ultravioleta. Se ha planteado que el trauma crónico puede predisponer a su desarrollo. El objetivo del presente estudio fue relacionar la presencia del MLA y sus características con las zonas acrales que se consideran de presión y de no presión. Material y métodos: Se realizó un estudio observacional, descriptivo, con intención analítica. Se recogieron los datos de 95 pacientes con diagnóstico de MLA evaluados en la Fundación Clínica Vida en Medellín, Colombia, entre enero de 2016 y agosto de 2020. Se recolectaron variables demográficas, histológicas y clínicas del tumor, las cuales se analizaron en dos grupos, según si estaba sometida a fuerzas de presión o no. Resultados: Se incluyeron 95 pacientes con MLA (36 hombres y 59 mujeres), con una mediana de edad de 59 años. Se presentaron más melanomas en las zonas de presión que de no presión (58 [61%] vs. 17 [17,8%]). Se refirió la existencia de un trauma directo previo en 18,9% de los casos, el cual fue más frecuente en las lesiones de las uñas (p = 0,025). Los melanomas invasores tuvieron un mayor Breslow (p = 0,006) y presencia de ulceración (p = 0,018) en las zonas de presión y en las uñas que en las zonas de no presión. Conclusiones: El MLA es más frecuente en zonas de presión que de no presión, tanto en la mano como en el pie. Esto apoya la hipótesis de que el estrés mecánico puede jugar un papel en la patogénesis de este tipo de tumor (AU)


Background and objective: Acral lentiginous melanoma (ALM) arises in areas that are not generally exposed to UV radiation. Chronic trauma has been hypothesized to play a role in the development of this tumor. The aim of this study was to analyze the association between the presence and characteristics of ALM and location in stress- and non–stress-bearing areas. Material and methods: Observational, descriptive analysis. For 95 patients with ALM evaluated at Fundación Clínica Vida in Medellin, Colombia between January 2016 and August 2020 we collected demographic, histologic and clinical variables and assigned the patients to 2 groups depending on whether their tumor was located in a stress-bearing area or not. Results: Ninety-five patients (36 men and 59 women) with a median age of 59 years were studied. ALMs were more common in stress-bearing areas than in non–stress-bearing areas (58 [61%] vs. 17 [17.8%]). A history of direct trauma at the site of the tumor was reported in 18.9% of the cases (p = .025) and was most common in patients with nail lesions. Invasive ALMs in stress-bearing areas had a greater Breslow thickness (p = .006) and higher ulceration rates than those in non–stress-bearing areas (p = .018). Conclusions: ALM on both the feet and hands is more common in stress-bearing areas. Our findings support the hypothesis that mechanical stress may have a pathogenic role in ALM (AU)


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Melanoma/patologia , Neoplasias Cutâneas/patologia , Estudos Retrospectivos , Estadiamento de Neoplasias , Fatores de Risco
3.
Actas dermo-sifiliogr. (Ed. impr.) ; 113(2): t134-t140, Feb. 2022. ilus, tab
Artigo em Inglês | IBECS | ID: ibc-205922

RESUMO

Background and objective: Acral lentiginous melanoma (ALM) arises in areas that are not generally exposed to UV radiation. Chronic trauma has been hypothesized to play a role in the development of this tumor. The aim of this study was to analyze the association between the presence and characteristics of ALM and location in stress- and non–stress-bearing areas. Material and methods: Observational, descriptive analysis. For 95 patients with ALM evaluated at Fundación Clínica Vida in Medellin, Colombia between January 2016 and August 2020 we collected demographic, histologic and clinical variables and assigned the patients to 2 groups depending on whether their tumor was located in a stress-bearing area or not. Results: Ninety-five patients (36 men and 59 women) with a median age of 59 years were studied. ALMs were more common in stress-bearing areas than in non–stress-bearing areas (58 [61%] vs. 17 [17.8%]). A history of direct trauma at the site of the tumor was reported in 18.9% of the cases (p = .025) and was most common in patients with nail lesions. Invasive ALMs in stress-bearing areas had a greater Breslow thickness (p = .006) and higher ulceration rates than those in non–stress-bearing areas (p = .018). Conclusions: ALM on both the feet and hands is more common in stress-bearing areas. Our findings support the hypothesis that mechanical stress may have a pathogenic role in ALM (AU)


Antecedentes y objetivo: El melanoma lentiginoso acral (MLA) se presenta en zonas con poca exposición a la radiación ultravioleta. Se ha planteado que el trauma crónico puede predisponer a su desarrollo. El objetivo del presente estudio fue relacionar la presencia del MLA y sus características con las zonas acrales que se consideran de presión y de no presión. Material y métodos: Se realizó un estudio observacional, descriptivo, con intención analítica. Se recogieron los datos de 95 pacientes con diagnóstico de MLA evaluados en la Fundación Clínica Vida en Medellín, Colombia, entre enero de 2016 y agosto de 2020. Se recolectaron variables demográficas, histológicas y clínicas del tumor, las cuales se analizaron en dos grupos, según si estaba sometida a fuerzas de presión o no. Resultados: Se incluyeron 95 pacientes con MLA (36 hombres y 59 mujeres), con una mediana de edad de 59 años. Se presentaron más melanomas en las zonas de presión que de no presión (58 [61%] vs. 17 [17,8%]). Se refirió la existencia de un trauma directo previo en 18,9% de los casos, el cual fue más frecuente en las lesiones de las uñas (p = 0,025). Los melanomas invasores tuvieron un mayor Breslow (p = 0,006) y presencia de ulceración (p = 0,018) en las zonas de presión y en las uñas que en las zonas de no presión. Conclusiones: El MLA es más frecuente en zonas de presión que de no presión, tanto en la mano como en el pie. Esto apoya la hipótesis de que el estrés mecánico puede jugar un papel en la patogénesis de este tipo de tumor (AU)


Assuntos
Humanos , Masculino , Feminino , Idoso , Idoso de 80 Anos ou mais , Melanoma/patologia , Neoplasias Cutâneas/patologia , Estudos Retrospectivos , Estadiamento de Neoplasias , Fatores de Risco
4.
Rev. chil. cardiol ; 40(3): 203-2010, dic. 2021. ilus
Artigo em Espanhol | LILACS | ID: biblio-1388097

RESUMO

Resumen: Introducción: Las células de la musculatura lisa vascular (CMLV) se caracterizan por mantener cierto grado de desdiferenciación, variando su fenotipo entre el contráctil y el secretor, de acuerdo con las necesidades del tejido, y el contráctil predominante en condiciones fisiológicas. Cualquier alteración del estímulo mecánico, ya sea en el flujo sanguíneo o la tensión mecánica ejercida sobre las CMLV, conducen a cambios de su fenotipo y remodelamiento de la vasculatura, lo que puede constituir el punto de inflexión de varias patologías relevantes en la salud pública como, por ejemplo, la hipertensión arterial. Objetivo: Realizar una revisión sobre los mecanosensores y las vías transduccionales conocidas e implicadas en el cambio de fenotipo de las CMLV. Metodología: Se realizó una búsqueda sistemática en las bases de datos PubMed, Scopus, Google Académico y Scielo sobre la mantención y cambio de fenotipo de las células de la musculatura lisa vascular asociado principalmente a el estrés mecánico, la participación de los mecanosensores más relevantes y las vías de señalización involucrados en este proceso. Conclusión: Los mecanosensores implicados en el cambio de fenotipo de las CMLV contemplan principalmente receptores acoplados a proteína G, moléculas de adhesión y canales iónicos activados por estiramiento. Los estudios se han concentrado en la activación o inhibición de vías como las proteínas quinasas activadas por mitógenos (MAPK), la vía AKT, mTOR y factores transcripcionales que regulan la expresión de genes de diferenciación y/o desdiferenciación, como las miocardinas. Existen además otros receptores involucrados en la respuesta al estrés mecánico, como los receptores tirosina quinasas. A pesar de la importancia que reviste el conocimiento de los mecanosensores y las vías implicadas en el cambio de fenotipo de las CMLV, así como el papel que cumplen en el establecimiento de patologías vasculares, es aún escaso el conocimiento que se tiene sobre los mismos.


Abstract: Introduction: Vascular smooth muscle cells (VS- MCs) are characterized by maintaining a certain de- gree of dedifferentiation. VSMCs may vary their phenotype between contractile and secretory according to tissue needs. Under physiological conditions, the predominant phenotype is contractile. Any alteration of the mechanical stimulus, either in the blood flow or the mechanical stress exerted on the VSMCs, leads to changes in their phenotype and remodeling of the vasculature. These changes can constitute the turning point in several hypertension and other diseases relevant in public health. Objective: To review the main mechanosensor and transduction pathways involved changes in VSMCs phenotype. Methods: A systematic search of PubMed, Scopus, Google Scholar and Scielo databases was carried out to ascertain the state of the art regarding the maintenance and change of VSMCs phenotype mainly associated with mechanical stress. Additionally, the participation of the most relevant mechanosensors and the signaling pathways involved in this process are discussed. Conclusion: The mechanosensors involved in the change in VSMCs phenotype mainly contempla- te G-protein-coupled receptors, adhesion molecules, and stretch-activated ion channels. Studies have been focused on the activation or inhibition of MAPK, AKT, mTOR, pathways and transcriptional factors that regulate the expression of differentiation and/or des differentiation genes such as Myocardins. There are also other receptors involved in the response to mechanical stress such as the tyrosine kinases receptor. Although the importance of understanding mechanosensors, the signaling pathways involved in VSMC phenotype switching and their role in the establishment of vascular pathologies, knowledge about them is limited.


Assuntos
Humanos , Estresse Mecânico , Miócitos de Músculo Liso/fisiologia , Mecanotransdução Celular , Músculo Liso Vascular/fisiologia , Fenótipo
5.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1385707

RESUMO

ABSTRACT: This study aims to evaluate the physical, chemical, mechanical and optical properties of Bulk-Fill resin, in relation to the literature and its proper clinical uses. A bibliographic search was performed in the main health databases PUBMED (www.pubmed.gov) and Scholar Google (www.scholar.google.com.br), in which articles published from 1994 to 2020 were collected. Laboratory studies, case reports, systematic reviews and literature reviews, which were developed in living individuals, were included. Therefore, articles that did not deal with the characteristics of the Bulk-Fill resin and its proper clinical uses were excluded. The use of Bulk-Fill resin has been progressively increasing over the years, presenting good properties, achieving success in clinical performance, ease of handling and thus has become the material of choice for dentists. In addition, its longevity demonstrates durability with mechanical properties and resistance to tooth structure. Bulk - Fill resins have characteristics similar to traditional composite resins, when performed according the usage protocol. With the use of this group of resins in a single increment, possible failures that occur during the restorative procedure can be minimized, such as: less chance of incorporating bubbles and a volumetric contraction with less stress on the interface.


RESUMEN: Este estudio tuvo como objetivo evaluar las propiedades físicas, químicas, mecánicas y ópticas de la resina Bulk-Fill, en relación con la literatura y sus usos clínicos apropiados. Realizamos una búsqueda bibliográfica en las bases de datos de salud PUBMED (www.pubmed.gov) y Scholar Google (www.scholar.google.com.br), en la que se recopilaron trabajos que se publicaron entre 1994 y 2020. Fueron incluidos estudios de laboratorio, informes de casos, revisiones sistemáticas y revisiones de literatura, desarrollados en individuos vivos. Por tanto, se excluyeron los artículos que no trataban las características de la resina Bulk-Fill y sus usos clínicos adecuados. El uso de la resina Bulk-Fill ha ido aumentando progresivamente a lo largo de los años, presentando buenas propiedades, logrando éxito en el rendimiento clínico, facilidad de manejo y, por lo tanto, se ha convertido en el material elegido por los dentistas. Además, su longevidad demuestra durabilidad, con propiedades mecánicas y resistencia a la estructura dental.Las resinas Bulk-Fill tienen características similares a las resinas compuestas tradicionales, cuando se realizan siguiendo el protocolo de uso. Con el uso de este grupo de resinas mono incremental, es posible eliminar el paso de varios incrementos, disminuyendo a su vez el tiempo clínico. Además, se pueden minimizar las posibles fallas que se producen durante el procedimiento de restauración, tales como: menos posibilidades de incorporar burbujas y una contracción volumétrica con menos estrés en la interfaz.

6.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1385736

RESUMO

ABSTRACT: To evaluate Knoop microhardness and diametral compression strength at different polymerization times. A total of 80 cylindrical samples with Filtek resin™ One Bulk Fill were made to perform the in vitro study, using half of total samples (n=40) for each test and divided equally between groups (n=10). All samples were made according to ISO 4049 using 2 mm thickness Teflon matrix and a central orifice with 4 mm diameter. Four different times of light-curing in Standard mode suggested by the light-unit manufacturer were selected, therefore, group 1 samples (G1) were light-cured for 5 seconds; group 2 (G2) for 10 seconds; group 3 (G3) for 15 seconds, and group 4 (G4) for 20 seconds. A radiant display, which means a power in mW/cm2 by time in seconds was expressed in Joules (J). The samples were stored in a dark container with distilled water at a temperature of 37°C for 48 hours before testing. One-way analysis of variance (ANOVA) with T-Test (LSD) of multiple comparisons of the mean values of Knoop hardness and diametral compression strength was performed, with significance index α=0.05. Regarding the Knoop microhardness test, G1 (35.73 ± 6.2) presented the lowest values, followed by G2, while G3 and G4 did not present statistical differences between them. For the diametral compression test, G1 (1387.76 ± 190.51) obtained the lowest value when compared to the other groups. G2, G3, and G4 did not present significant statistical differences. The different polymerization times influenced the Knoop microhardness and the diametral compression strength of Bulk Fill resin.


RESUMEN: El objetivo de este trabajo fue evaluar la microdureza Knoop y la resistencia a la compresión diametral en diferentes tiempos de polimerización. En el estudio realizado in vitro, se analizó un total de 80 muestras cilíndricas con la resina Filtek™ One Bulk Fill, utilizando la mitad (n=40) para cada prueba realizada y dividida en partes iguales entre los grupos (n=10). Todas las muestras se tomaron de acuerdo con ISO 4049 utilizando matrices de teflón de 2 mm de espesor y orificio central con 4 mm de diámetro. Se seleccionó cuatro veces el fotocurado de manera estándar, sugerido por el fabricante. Por lo tanto, las muestras del grupo 1 (G1) se fotopolimerizaron durante 5 segundos; grupo 2 (G2) durante 10 segundos; grupo 3 (G3) durante 15 segundos y grupo 4 (G4) durante 20 segundos. La exposición radiante, que indica la potencia en mW / cm2 a lo largo del tiempo en segundos, se expresó en julios (J). Las muestras se almacenaron en un recipiente oscuro con agua destilada en una estufa a una temperatura de 37°C durante 48 horas antes del ensayo. Se realizó para comparaciones múltiples de los valores medios, análisis de varianza (ANOVA) de un criterio con la prueba T (LSD) tanto de la dureza de Knoop como de la compresión diametral con un índice de significación α=0.05. Con respecto a la prueba de microdureza de Knoop, G1 (35,73 ± 6,2) tuvo los valores más bajos, seguido de G2, mientras que G3 y G4 no mostraron diferencias estadísticas entre ellos. Para la prueba de compresión diametral, G1 (1387.76 ± 190.51) obtuvo el valor más bajo en comparación con los otros grupos. G2, G3 y G4 no presentaron diferencias estadísticamente significativas. Los diferentes tiempos de polimerización influyeron en la microdureza de Knoop y la resistencia a la compresión diametral de la resina compuesta mono incremental.

7.
Odontología (Ecuad.) ; 22(2): 45-59, 2020.
Artigo em Espanhol | LILACS | ID: biblio-1103546

RESUMO

En conductos radiculares curvos, la utilización de limas que eviten desvíos y fracturas del instrumento por fatiga y que mantengan curvaturas originales son aspectos importantes en el tratamiento endodóntico. Ob-jetivo: Se evaluó la resistencia a la fatiga cíclica de cuatro sistemas reciprocantes en una canaleta dinámica que simuló tres curvaturas diferentes. Materiales y Método: Estudio in vitro; la muestra con 48 limas se dividió en cuatro grupos (n= 12/grupo): WaveOne® (WO), WaveOne® Gold (WOG), Reciproc® (R) y Reciproc® Blue (RB), cuatro limas de cada sistema se usaron en una canaleta que simuló tres angulaciones 45°, 60° y 90°; montadas en un motor X-Smart Plus®, las limas se introdujeron 23 mm en los conductos para ser activadas continuamente a 300/500 oscilaciones/minuto hasta que se produjo la fractura. Se registró tiempo y zona de fractura. Se realizó el test Kruskal Wallis con un nivel de confianza del 95% para las comparaciones. Resul-tados: RB presentó mayor resistencia a la fatiga cíclica que WO y WOG en todas las angulaciones y que R a 90° (p= <0,05). R presentó mayor resistencia que WOG a 45° y 60°, sin embargo, a 90° WOG fue superior que R y WO (p<0,05). No hubo diferencias en cuanto a la zona de fractura que aconteció en la porción apical. Conclusiones: La resistencia se reduce cuando aumenta el grado de curvatura. RB fue significativamente más resistente a la fatiga cíclica que WO y WOG en todas las angulaciones y que R a 90°. La zona de fractura se produjo en la porción apical de las limas.


In the curved canals, the use of files that avoid deviations and fractures of the instrument due to fatigue and that maintain original curvatures are important aspects in endodontic treatment. Objective: The resistance to cyclic fatigue of four reciprocating systems was evaluated in a dynamic gutter that stimulated three different curvatures. Materials and Method: In vitro study, the sample with 48 files was divided into four groups (n = 12 /group): WaveOne® (WO), WaveOne® Gold (WOG), Reciproc® (R) and Reciproc® Blue (RB), four files from each system were used in a gutter that simulated three angulations 45o , 60 o and 90 o . The files which were mounted on an X-smart Plus® were inserted 23 mm into the conduits to be continuously activated at 300/500 oscillations per minute until the fracture occurred. Time and fracture zone were recorded. The Krustal Wallis test was performed with a 95% confidence level for the comparisons. Results: RB presented greater resis-tance to cyclic fatigue than WO and WOG at 45o and 60o, however, at 90o WOG was higher than R and WO (p<0.05). There were no differences regarding the fracture zone occurred in the apical portion. Conclusions: The resistance decreases when the degree of curvature increases. RB was significantly more resistance to cyclic fatigue than WO and WOG at all angulations and R at 90o. The fracture zone occurred in the apical portion of the files.


Em canais radiculares curvos, o uso de limas que evitem desvios e fraturas do instrumento devido à fadiga e que mantêm as curvaturas originais são aspectos importantes no tratamento endodôntico. Objetivo: avaliar a resistência à fadiga cíclica de quatro sistemas reciprocantes em uma canaleta artificial que simula três curva-turas diferentes. Materiais e Método: estudo in vitro; a amostra com 48 limas foi dividida em quatro grupos (n = 12 / grupo): WaveOne® (WO), WaveOne® Gold (WOG), Reciproc® (R) e Reciproc® Blue (RB), quatro limas de cada sistema foram usadas em uma canaleta que simulo três angulações 45 °, 60 ° e 90 °; se montaram em um motor X Smart Plus®, as limas foram inseridas 23 mm nos condutos para serem ativadas continuamente a 300/350 oscilações / minuto até ocorrer uma fratura. O tempo e a zona de fratura foram registrados. O teste de Kruskal Wallis foi realizado com um nível de confiança de 95% para as comparações. Resultados: O RB apresenta maior resistência à fadiga cíclica que o WO e o WOG em todas as angulações e que R a 90 ° (p = <0,05). R apresentou maior resistência que WOG a 45 ° e 60 °, no entanto, a 90 ° WOG foi maior que R e WO (p <0,05). No existiu diferença na zona de fratura que ocorreu na porção apical. Conclusões: a resistência diminui quando o grau de curvatura aumenta. RB foi significativamente mais resistente à fadiga cíclica do que WO e WOG em todos os ângulos e R a 90 °. A zona de fratura ocorre na parte apical das limas.


Assuntos
Cavidade Pulpar , Endodontia , Resistência à Flexão , Estresse Mecânico , Técnicas In Vitro
8.
Rev. chil. cardiol ; 38(1): 29-36, abr. 2019. graf
Artigo em Espanhol | LILACS | ID: biblio-1003635

RESUMO

Resumen: Antecedentes: La muerte de los cardiomiocitos es determinante en el desarrollo de patologías cardiacas posteriores al infarto del miocardio y la insuficiencia cardiaca. Las variaciones en la expresión de la familia de proteínas BCL-2 regulan vías, tanto de muerte, como de sobrevida celular. Así, BCL-2 es una proteína anti- apoptótica y NIX una proteína que induce la necrosis y/o la apoptosis celular. La Policistina-1 (PC1) es un mecanosensor vital para la función contráctil cardiaca; sin embargo, se desconoce su papel en la sobrevida de los cardiomiocitos durante el estrés mecánico. Objetivo: Determinar si PC-1 previene la muerte de los cardiomiocitos inducida por estrés mecánico y las proteínas BCL-2 y NIX. Métodos: Se utilizó cultivo de cardiomiocitos de ratas neonatas controles o deficientes en la expresión de PC1, estimulados con solución hiposmótica (HS), como modelo de estrés mecánico. Se midió la muerte por necrosis y apoptosis y los niveles de BCL-2 y NIX. Resultados: La deficiencia de la PC1 en los cardiomiocitos induce un aumento de la necrosis y los niveles proteicos de NIX en las células estimuladas con HS. El estrés mecánico induce la apoptosis basal relacionada a una disminución de BCL- 2, independiente de la expresión de la PC1. Conclusiones: La PC1 protege a los cardiomiocitos de la necrosis por estrés mecánico, lo que podría deberse en parte a su papel en la regulación de los niveles de las proteínas NIX.


Abstracts: Background: Cardiomyocytes death is a determining factor in the development of cardiac dysfunction after myocardial infarction and heart failure. The change in BCL-2 family protein expression regulates both cell death and survival pathways, whereas BCL-2 is an anti-apoptotic protein and NIX induces necrosis and/or apoptosis. Polycystin-1 (PC1) is a crucial mechanosensor for cardiac contractile function. However, its role in cardiomyocyte survival during mechanical stress is unknown. Aim: To study the relationship of PC1 with mechanical stretch-death in cardiomyocytes and the BCL-2, and NIX proteins. Methods. Controls or deficient expression of PC1 neonatal rat ventricular myocytes were stimulated with hypoosmotic solution (HS) and used as a model of mechanical stress. Necrosis or apoptosis cell death, BCL-2 and NIX protein levels were measured. Results: Deficient expression of PC1 increases cardiomyocyte necrosis and NIX protein levels in cells stimulated with HS. Mechanical stress induces basal apoptosis related to a decrease in BCL-2, independent of PC1 expression. Conclusion: PC1 protects cardiomyocytes from mechanical stress necrosis, at least in part, by regulating NIX protein levels.


Assuntos
Animais , Masculino , Ratos , Proteínas Proto-Oncogênicas c-bcl-2/metabolismo , Miócitos Cardíacos/metabolismo , Canais de Cátion TRPP/metabolismo , Necrose/prevenção & controle , Estresse Mecânico , Western Blotting , Ratos Sprague-Dawley , Apoptose , Citometria de Fluxo , Proteínas de Membrana/metabolismo
9.
J. oral res. (Impresa) ; 8(2): 108-115, abr. 30, 2019. ilus, tab, graf
Artigo em Inglês | LILACS | ID: biblio-1145301

RESUMO

Statement of problem : fracture of endodontically treated teeth is reduced by the use of a post with ferrule, but the effect of different ferrule configurations and dowel materials is not clear. Purpose: to evaluate the effect of ferrules with different configurations and heights on the stress of endodontically treated teeth restored with three different post and dowel materials. Materials and Methods: fifteen models of maxillary central incisors restored with porcelain fused to metal crowns were obtained using pro engineer software. the models were divided into three groups, each consisting of five models with ferrule heights of 0mm, 2mm, 4mm, 2mm with oblique fracture, 4mm with oblique fracture, the models under group GFR were restored with fiberglass reinforced post (GFR) and composite core build-up, group NiCr with a custom cast post metal alloy (NiCr), and group Zr with zirconia post (Zr) and composite core build-up. an oblique load of 100N and 150N at an angle of 135 degrees was applied to the palatal surface of the tooth, a vertical load of 100N and 150N at an angle of 90 degrees was applied to the incisal tip of the tooth. The maximum principal stress and the von mises stress was calculated for the remaining tooth structure and post apex using the finite element analysis (FEA) software. Results: the maximum von misses stress was observed in the apex of the post (p<0.05). Group Zr showed the highest mean stress (6.39Mpa) followed by group NiCr (5.65Mpa). There was a significant difference between post and between NiCr and Zr post for 2mm and 4mm ferrule height, while for 0mm ferrule there was a significant difference between the GFR and NiCr groups (p<0.05). Under oblique load, the maximum mean stress was observed in remaining tooth structures while for vertical load, it was observed at the apex of the post. Regarding ferrule heights, there were significant differences between 0mm-2mm, and 0mm-4mm uniform ferrule in post apex in the case of NiCr posts (p<0.05). Absence of ferrule resulted in higher stress for the NiCr group. Conclusion: higher loads that led to fracture were observed only at the apex of the post. Zirconia posts (group Zr) had higher fracture loads, whereas absence of ferrule resulted in higher fracture load with custom cast posts (group NiCr). Fracture thresholds were high on the remaining tooth structure for all the dowel systems especially for composite core build up irrespective of ferrule height and configuration. Clinical implications: appropriate selection of post and dowel materials in different configurations of ferrule heights ensures clinical success.


Indicación del problema: la fractura de los dientes tratados endodónticamente se reduce mediante el uso de un poste con férula, pero el efecto de diferentes configuraciones de férula y materiales de clavija no está claro. Propósito: evaluar el efecto de los casquillos con diferentes configuraciones y alturas sobre el estrés de los dientes tratados endodónticamente restaurados con tres materiales diferentes de postes y tacos. materiales y métodos: quince modelos de incisivos centrales superiores restaurados con porcelana fundida a coronas de metal se obtuvieron con el software Pro Engineer. Los modelos se dividieron en tres grupos, cada uno de los cuales consta de cinco modelos con alturas de casquillo de 0mm, 2mm, 4mm, 2mm con fractura oblicua, 4mm con fractura oblicua. los modelos del grupo GFR fueron restaurados con poste reforzado con fibra de vidrio (GFR) y acumulación de núcleo compuesto, grupo nicr con una aleación de metal de poste fundido personalizado (NiCr) y grupo Zr con poste de zirconia (Zr) y acumulación de núcleo compuesto. se aplicó una carga oblicua de 100N y 150N en un ángulo de 135º a la superficie palatina del diente. se aplicó una carga vertical de 100N y 150N en un ángulo de 90º a la punta incisal del diente. la tensión principal máxima y la tensión de von mises se calcularon para la estructura dental restante y después del vértice utilizando el software de análisis de elementos finitos (FEA). Resultados: el estrés máximo de von falta se observó en el vértice de la publicación (p<0.05). El grupo Zr mostró el mayor estrés medio (6.39Mpa) seguido del grupo NiCr (5.65Mpa). Hubo una diferencia significativa entre la publicación NiCr y Zr para la altura de la férula de 2mm y 4mm, mientras que para la férula de 0mm hubo una diferencia significativa entre los grupos GFR y NiCr (p<0,05), bajo la carga oblicua, la tensión media máxima en las estructuras dentales restantes, mientras que para la carga vertical, se observó en el vértice del poste. En cuanto a las alturas de la férula, hubo diferencias significativas entre la férula uniforme de 0mm-2mm y de 0mm-4mm en el post-apex en el caso de los postes de NiCr (p<0.05), la ausencia de férula dio como resultado un mayor estrés para el grupo NiCr. Conclusión: las cargas más altas que llevaron a la fractura se observaron solo en el vértice del poste; Los postes de zirconia (grupo Zr) tuvieron mayores cargas de fractura, mientras que la ausencia de férula dio como resultado una mayor carga de fractura con postes moldeados personalizados (NiCr de grupo). Los umbrales de fractura fueron altos en la estructura dental restante para todos los sistemas de clavijas, especialmente para la acumulación de núcleos compuestos independientemente de la altura y configuración de la férula. Implicaciones clínicas: la selección adecuada de materiales de postes y tacos en diferentes configuraciones de alturas de férulas asegura el éxito clínico.


Assuntos
Humanos , Técnica para Retentor Intrarradicular/instrumentação , Análise do Estresse Dentário/métodos , Incisivo/fisiologia , Modelos Biológicos , Estresse Mecânico , Fraturas dos Dentes , Simulação por Computador , Planejamento de Prótese Dentária , Desenho Assistido por Computador , Materiais Dentários/química , Maxila/fisiologia
10.
Fisioter. Mov. (Online) ; 32: e003203, 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-984392

RESUMO

Abstract Introduction: Some authors have described the importance of physiological intensity in the behavior of the biomechanical aspects of running (for example, subtalar pronation), but the complex relationships between these variables are not yet well understood. Objective: This study investigated the influence of positive gradients on internal mechanical work (Wint) and maximum subtalar pronation at a submaximal running speed. Method: Sixteen male, trained long-distance runners (age: 29 ± 7 yr; stature: 1.72 ± 0.07 m; body mass: 72.1 ± 10.6 kg), performed four running economy tests (gradients: +1%, +5%, +10% and +15%, respectively) for four minutes at a same submaximal running speed to quantify the maximum values of subtalar pronation and predict the Wint values. Data were analyzed using descriptive statistics, Student's T-test, and one-way repeated-measures (ANOVA) along with the Statistical Package for the Social Sciences (SPSS) version 20.0. Results: Wint increased according to the gradient (p < 0.05). However, no significant differences were observed in the maximum values of maximum subtalar pronation corresponding to each gradient. Conclusion: Results show the maximum subtalar pronation during submaximal running depends on the speed rather than intensity of effort.


Resumo Introdução: Autores têm descrito a importância da intensidade fisiológica no comportamento dos aspectos biomecânicos da corrida (por exemplo, a pronação subtalar), mas as complexas relações entre essas variáveis todavia não estão bem compreendidas. Objetivo: O presente estudo investigou a influência de gradientes de inclinação positivos, a uma mesma velocidade de corrida, no trabalho mecânico interno (Wint) e na máxima pronação subtalar. Método: Dezesseis corredores masculinos, especialistas em longas-distâncias (idade: 29 ± 7 anos; estatura: 1,72 ± 0,07 m; massa corporal: 72,1 ± 10,6 kg) realizaram quatro testes de economia de corrida (gradientes: +1%, +5%, +10% e +15%, respectivamente), de quatro minutos cada, em uma mesma velocidade submáxima de corrida, objetivando quantificar os valores de máxima pronação subtalar e predizer os Wint. Foi realizada a análise descritiva e aplicados os testes T de Students e ANOVA de Medidas Repetidas, todos através do software Statistical Package for the Social Sciences (SPSS), versão 20.0. Resultados: O Wint aumentou com o gradiente (p < 0,05). Entretanto, diferenças estatisticamente significativas não foram observadas nos valores de máxima pronação subtalar correspondentes a cada gradiente. Conclusão: Os resultados do presente estudo revelam que a máxima pronação subtalar durante a corrida submáxima é dependente da velocidade em comparação a intensidade de esforço.


Resumen Introducción: Autores tienen descrito la importancia de la intensidad fisiológica en el comportamiento de los aspectos biomecánicos de la carrera (por ejemplo, la pronación subtalar), mas las complejas relaciones entre esas variables todavía no están bien comprendidas. Objetivo: El presente estudio investigó la influencia de gradientes de inclinación positivos, a una misma velocidad de carrera, en el trabajo mecánico interno (Wint) y en la máxima pronación subtalar. Método: Dieciséis corredores masculinos, especialistas en largas-distancias (edad: 29 ± 7 años; estatura: 1,72 ± 0,07 m; masa corporal: 72,1 ± 10,6 kg) realizaron cuatro testes de economía de carrera (gradientes: +1%, +5%, +10% e +15%, respectivamente), de cuatro minutos cada, en una misma velocidad submáxima de carrera, objetivando cuantificar los valores de máxima pronación subtalar y predecir los Wint. Fue realizada la análisis descriptiva y aplicados los testes T de Students y ANOVA de Medidas Repetidas, todos realizados en el software Statistical Package for the Social Sciences (SPSS), versión 20.0. Resultados: EL Wint aumentó con el gradiente (p < 0,05). Entretanto, diferencias estadísticamente significativas no fueran observadas en los valores de máxima pronación subtalar correspondientes a cada gradiente. Conclusión: Los resultados del presente estudio revelan que la máxima pronación subtalar durante la carrera submáxima es dependiente de la velocidad en comparación a la intensidad del esfuerzo.


Assuntos
Humanos , Masculino , Corrida , Traumatismos do Tornozelo , Teste de Esforço , Estresse Mecânico
11.
Rev. cuba. ortop. traumatol ; 29(2): 0-0, jul.-dic. 2015. ilus, graf
Artigo em Espanhol | CUMED | ID: cum-64425

RESUMO

El envejecimiento y la degeneración producen cambios en la columna vertebral, los discos pierden la capacidad de cumplir sus funciones. Se realizó una revisión critica acerca de la degeneración del disco intervertebral, el dolor y la estabilidad de la columna lumbar para lo cual se examinaron los avances en el conocimiento del proceso de degeneración discal, los factores que influyen en este fenómeno y los procesos celulares que tienen lugar en él, así como la clasificación anatomopatológica más empleada y su reflejo en imágenes de resonancia. Los cambios celulares en el disco ocurren a través de seis procesos que ocasionan cambios bioquímicos en la matriz extracelular y pérdida de las funciones. Las células desempeñan el papel principal en los cambios biológicos y bioquímicos de la degeneración del disco intervertebral. En este proceso, además del envejecimiento, participan otros factores como: predisposición genética, aporte nutricional y de oxígeno y el estrés mecánico(AU)


Aging and degeneration result in changes in the spine; the discs lose their ability to fulfill their functions. A critical review on the intervertebral disc degeneration, pain and stability of the lumbar spine was carried out for which progress in the understanding of disc degeneration process, the influence factors and its cellular processes, as well as the most widely used pathologic classification and its reflection in resonance images were reviewed. The disk cell changes occur through six processes; which causes biochemical changes in the extracellular matrix and loss of function. Cells play the major role in biological and biochemical changes of intervertebral disc degeneration. Genetic predisposition, nutritional and oxygen supply and mechanical stress are involved as other factors in this process, in addition to aging(AU)


Assuntos
Humanos , Degeneração do Disco Intervertebral/patologia , Dor Lombar/epidemiologia , Fatores de Risco , Predisposição Genética para Doença/epidemiologia , Estresse Mecânico , Senescência Celular
12.
Rev. cuba. ortop. traumatol ; 29(2): 143-157, jul.-dic. 2015. ilus
Artigo em Espanhol | LILACS, CUMED | ID: lil-771817

RESUMO

El envejecimiento y la degeneración producen cambios en la columna vertebral, los discos pierden la capacidad de cumplir sus funciones. Se realizó una revisión critica acerca de la degeneración del disco intervertebral, el dolor y la estabilidad de la columna lumbar para lo cual se examinaron los avances en el conocimiento del proceso de degeneración discal, los factores que influyen en este fenómeno y los procesos celulares que tienen lugar en él, así como la clasificación anatomopatológica más empleada y su reflejo en imágenes de resonancia. Los cambios celulares en el disco ocurren a través de seis procesos que ocasionan cambios bioquímicos en la matriz extracelular y pérdida de las funciones. Las células desempeñan el papel principal en los cambios biológicos y bioquímicos de la degeneración del disco intervertebral. En este proceso, además del envejecimiento, participan otros factores como: predisposición genética, aporte nutricional y de oxígeno y el estrés mecánico.


Aging and degeneration result in changes in the spine; the discs lose their ability to fulfill their functions. A critical review on the intervertebral disc degeneration, pain and stability of the lumbar spine was carried out for which progress in the understanding of disc degeneration process, the influence factors and its cellular processes, as well as the most widely used pathologic classification and its reflection in resonance images were reviewed. The disk cell changes occur through six processes; which causes biochemical changes in the extracellular matrix and loss of function. Cells play the major role in biological and biochemical changes of intervertebral disc degeneration. Genetic predisposition, nutritional and oxygen supply and mechanical stress are involved as other factors in this process, in addition to aging.


Le vieillissement et la dégénérescence provoquent des changements au niveau du rachis. Les disques vertébraux perdent la capacité de réaliser leurs fonctions. Une revue critique de littérature a été effectuée sur la dégénérescence des disques intervertébraux, la douleur et la stabilité du rachis. C’est pourquoi, on a examiné les nouvelles informations concernant le processus de dégénérescence discale, les facteurs influant sur ce phénomène et les processus cellulaires en développement, ainsi que la classification anatomo-pathologique la plus souvent utilisée et les images par RM. Les changements cellulaires du disque se produisent à travers six processus conduisant à des changements biochimiques de la matrice extracellulaire et une perte des fonctions. Les cellules jouent un rôle essentiel dans les changements biologiques et biochimiques de la dégénérescence du disque intervertébral. En plus du vieillissement, il y a d’autres facteurs tels que la prédisposition génétique, l’apport nutritionnel et d’oxygène et le stress mécanique, qui participent dans ce processus.


Assuntos
Humanos , Estresse Mecânico , Fatores de Risco , Senescência Celular , Dor Lombar/epidemiologia , Predisposição Genética para Doença/epidemiologia , Degeneração do Disco Intervertebral/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...